Software, Drivers, Documents | LabView | Catalogues

Drivers

USB driver for IF-U1/IF-U2/IF-E1/IF-E2

Note: contains drivers for Windows 98/ME, XP/Vista and Windows 7 (32 & 64bit). The driver is a combined driver. It means, it can work as a true USB driver and it creates a COM port for every USB port of an interface card that is installed, which then can be accessed as a RS232 interface.
This virtual COM port (VCP) is activated by default after the installation! It can to be deactivated in the driver setup dialogue (Windows device manager), if only the USB functionality is required.

Download: USB driver

Experiencing problems with the driver installation? Click here.

Profibus GSD (GSE)

Here you can find so-called Generic Station Device files (GSD) for the implementation of our devices into a Profibus. English version of the GSD files is *.GSE. Supported series:

- Power supply series PSI 8000
- Power supply series PS 8000
- Power supply series PS 9000

Support for the Profibus interface card in other devices upon request.

Also refer to the documentation of our digital interface cards, section "Profibus", to learn about the supported datagrams.

Download: Profibus GSD/GSE for power supplies

 

IP-Config for Ethernet card IF-Ex

This tool is used to adjust network parameters  (IP, subnet mask, gateway) of  a device where these parameters can't be set on the device itself. This pre-configuration is done via the additional USB port of the Ethernet card. After the setup, the device can be integrated into a network and is instantly accessible.

The tool is based on Labview and requires a runtime engine. In case the required runtime engine is already installed on your PC, by a different software from us, then please download the much smaller version without runtime, delete everything in the installation folder and unpack the ZIP file to there.

Download: IP-Config without runtime (0.2MB)

Download: IP-Config with runtime (113.8MB)

EasySoft Update Tool

The EasySoft update tool is used for manual firmware updates on site. The user just installs the application on Windows and then only needs the firmware file (not included), which is obtainable here for the particular device. Following device series and interface cards are compatible for updates:

  • PSI 8000 T / DT / 2U
  • PSI 9000
  • PSI 800 R
  • EL 3000
  • EL 9000
  • EL 9000 HP
  • PS 8000 T / DT / 2U
  • IF-G1
  • IF-E1/IF-E1b

 

Restrictions:

  • Updating devices is only possible with an USB or RS232 interface card ( IF-Ux, IF-Ex or IF-Rx)!
  • The interface card IF-G1 can not be used to update a device!

 

Minimum requirements:

  • PC with Windows XP or newer, 512MB RAM, approx. 150MB harddrive space, 1x COM-Port or 1x USB
  • Device with interface card and proper cable (e.g. null modem cable, not included)

 

Attention! Please update versions prior to 3.03, in order to avoid problems with newer firmware files.

EasySoft Update Tool 3.05 (110MB) *

*LabView based, installs a runtime engine and services. The services may be deactivated, if not used otherwise.

 

Firmware files:

Note: Select the proper file according to the series your device is from (e.g. PSI 8160-04 R --> series PSI 800 R). Do not try to unpack the file, just open it in the update tool as it is!

PS 8000 T

Current version: v6.11
History

PS 8000 DT / DT HS

Current version: v6.11
History

PS 8000 2U / 2U HS / 3U

Current version: v6.11
History

PSI 8000 T / DT / 2U / 3U

Current version: 3.14
History

PSI 800 R

Current version: 2.06

PSI 9000

Current version: 4.03

EL 3000

Current version: 5.04 Note: updateable from v3.0
History

EL 9000 (HP)

Current version: 5.04 Note: updateable from v3.0
History

BCI 800 R

Current version: 3.01

Card IF-G1

Current version: 3.09
History

Cards IF-E1 / IF-E2

Current version: 2.03
(Attention! Only for articles 33100218 and 33100223)

Card IF-E1B

Current version: 2.08 (Attention! Only for article 33100227)
History