Software, Drivers, Documents | LabView | Catalogues

EasyPower

The new EasyPower software is intended for our digital lab power supplies of the PSI 9000 series. It requires one of the EA interface cards IF-R1 (RS232, 1 unit) or IF-U1 (USB, up to 30 units). EasyPower is also included on the CD that comes with the interface cards package. This download version is identical. The software is labview based and requires the LabView runtime engine which is automatically installed with the software. Click on the pictures to the left for screenshots.

The other interface cards for the PSI 9000 series, IF-C1 and IF-G1, are not compatible with EasyPower.

 

 

With the RS232 card IF-R1 only 1 unit can be controlled! With USB up to 30.

 

 

System requirements:

 

 

  • Windows XP PC with minimum 512MB RAM
  • Office XP or at least Excel XP (for data logging and export)
  • approx. 9MB hard disk space
  • one or multiple power supplies from the PSI 9000 series, equipped with either IF-R1 or IF-U1 card

 

The software offers following functions:

  • Monitoring of up to 30 power supplies at once in a window (30-view)
  • Monitoring and controlling of up to 5 out of max. 30 units in a window (5-view)
  • Monitoring, controlling, curve progression, configuration and more of 1 out of max. 30 units (1-view)
  • In the 30-view, the user can do following at 1 to 30 units:
    • read the actual values (current, voltage, power) of all units
    • switch the power output on/off
    • read errors/alarms and the current regulation mode (CC, CV etc.)
    • read the unit type string and the user text
    • switch to 5-view or 1-view
  • In the 5-view, the user can do following at 1 to 5 units:
    • adjust set values for current, voltage, power and resistance
    • read the actual values of current, voltage and power
    • switch the power output on/off
    • switch between manual (local) and remote control
    • read errors/alarms and the current regulation mode (CC, CV etc.)
    • read the unit type string and the user text
    • read the status of running sequences
    • start/stop the data logging feature (data are logged to an Excel sheet)
    • switch to 1-view or 30-view
  • In the 1-view, the user can completely control one selected unit like in the 5-view, but additionally:
    • use the sequence editor
    • configure the supervision
    • manage the curve progression diagram with many configurational possibilities
    • configure preset lists, limits and other settings
    • set up a user text (stored in the device)
    • configure and control the function manager
  • Data logging for up to 5 units at once. The actual values of current, voltage and power are recorded, together with a time stamp, into a Excel sheet in selectable intervals and with a selectable number of recorded entries
  • Curve progression diagram (only in 1-view), which shows the chronological progression of current, voltage and power (actual and set values) of the selected unit. The diagram can be configured

 

 

 

The package contains the software in english language, as well as a user manual in german and english. At questions or problems please contact us by mail to ea1974elektroautomatik.de or by the contact form (see above).

 

EasyPower v2.03, 15MB

  

Legal note: this software can only run with the above listed type of device. Any modification of content, name, logo or trademark, as well as resale, rental or other use is prohibited. Download and installation at one's own risk. Any damage, caused by the use of this software on a PC, is not subject of adherence of the vendor.

 

 

1-view
5-view
30-view

EasyPower Lite

 

The new EasyPower Lite software is intended for our digital lab power supplies of series PSI 8000T/DT/2U, PS 8000 T/DT/2U, PSI 800 R and PSI 9000 series. It requires one of the EA interface cards IF-R1/R2 (RS232, 1 unit), IF-U1/U2 (USB) or IF-E1/E2 (via the additional USB port). EasyPower Lite is also included on the CD that comes with the interface cards package. This download version is identical. The software is labview based and requires the LabView runtime engine which is automatically installed with the software. Click on the pictures to the left for screenshots.

The other interface cards IF-C1 and IF-G1, are not compatible with EasyPower Lite.

 

Hardware requirements:

  • Windows XP/2003/Vista
  • PC with mind. 512MB RAM
  • approx. 150MB hard drive space 
  • Lab power supply with interface card

 

The software offers following functions:

  • Monitoring and control of one device per running instance
  • Read actual values of current, voltage and power
  • Switch power output on/off
  • Device condition (errors, output, regulation mode)
  • Read device type string and read/edit user text
  • Adjust current/voltage/power set values
  • Activate/deactivate remote control
  • Load and run automated sequences from CSV file (current, voltage and time)
  • Data acquisition with actual and set values, date, time and condition to CSV file
  • Graphical display of the chronological progression of actual and set values

 

 

What is a sequence?
A sequence is a list of set values, together with a time. The user can define a set value for power, voltage and current and a time from 0,5s to 100h in a single line of a CSV file (exported from Excel or OpenOffice Calc). The number of line is virtually unlimited. When runing a sequence from that file, that device is automatically controlled by the software, executing the sequence file line-by-line. The time defines the distance between two steps. If a set value is changed from one step to the next, it is instantly set with the next step. The software or the device will not generate a ramp!

 

 

What does data acquisition log to file?
It logs actual values (U/I/P), set values (U/I/P), device status and a timestamp with date into a text file of type CSV (entries are spearated by semicolons). The interval is settable.

 

 

The package contains the software in english language, as well as a user manual in german and english. At questions or problems please contact us by mail to ea1974elektroautomatik.de or by the contact form (see above).

 

EasyPower Lite v2.02 with LabView Runtime, 98MB

EasyPower Lite User guide (PDF)

  

Legal note: this software can only run with the above listed type of device. Any modification of content, name, logo or trademark, as well as resale, rental or other use is prohibited. Download and installation at one's own risk. Any damage, caused by the use of this software on a PC, is not subject of adherence of the vendor. This software is Freeware and free of charge and does not claim to be complete, correct, exact or free from errors.

 

 

Main screen
Device selection
Configuration

Drivers

USB driver for IF-U1/IF-U2/IF-E1/IF-E2

Note: contains drivers for Windows 98/ME, XP/Vista and Windows 7 (32 & 64bit). The driver is a combined driver. It means, it can work as a true USB driver and it creates a COM port for every USB port of an interface card that is installed, which then can be accessed as a RS232 interface.
This virtual COM port (VCP) is activated by default after the installation! It can to be deactivated in the driver setup dialogue (Windows device manager), if only the USB functionality is required.

Download: USB driver

Experiencing problems with the driver installation? Click here.

EasySoft Update Tool

The EasySoft update tool is used for manual firmware updates on site. The user just installs the application on Windows and then only needs the firmware file (not included), which is obtainable here for the particular device. Following device series and interface cards are compatible for updates:

  • PSI 8000 T / DT / 2U
  • PSI 9000
  • PSI 800 R
  • EL 3000
  • EL 9000
  • EL 9000 HP
  • PS 8000 T / DT / 2U
  • IF-G1
  • IF-E1/IF-E1b

 

Restrictions:

  • Updating devices is only possible with an USB or RS232 interface card ( IF-Ux, IF-Ex or IF-Rx)!
  • The interface card IF-G1 can not be used to update a device!

 

Minimum requirements:

  • PC with Windows XP or newer, 512MB RAM, approx. 150MB harddrive space, 1x COM-Port or 1x USB
  • Device with interface card and proper cable (e.g. null modem cable, not included)

 

Attention! Please update versions prior to 3.03, in order to avoid problems with newer firmware files.

EasySoft Update Tool 3.05 (110MB) *

*LabView based, installs a runtime engine and services. The services may be deactivated, if not used otherwise.

 

Firmware files:

Note: Select the proper file according to the series your device is from (e.g. PSI 8160-04 R --> series PSI 800 R). Do not try to unpack the file, just open it in the update tool as it is!

PS 8000 T

Current version: v6.11
History

PS 8000 DT / DT HS

Current version: v6.11
History

PS 8000 2U / 2U HS / 3U

Current version: v6.11
History

PSI 8000 T / DT / 2U / 3U

Current version: 3.14
History

PSI 800 R

Current version: 2.06

PSI 9000

Current version: 4.03

EL 3000

Current version: 5.04 Note: updateable from v3.0
History

EL 9000 (HP)

Current version: 5.04 Note: updateable from v3.0
History

BCI 800 R

Current version: 3.01

Card IF-G1

Current version: 3.09
History

Cards IF-E1 / IF-E2

Current version: 2.03
(Attention! Only for articles 33100218 and 33100223)

Card IF-E1B

Current version: 2.08 (Attention! Only for article 33100227)
History