EA-ELEKTRO-AUTOMATIK Virtual stand on DirectIndustry.com
|
Virtual stand on |
|
Products - EA-ELEKTRO-AUTOMATIK
|
|
Battery charger
Switched mode, automatic battery chargers for wall mount or chassis mount, cooled by fan or air circulation, customer specific charging curves programmable, pre-programmed for the most common battery types (selectable)
- Mains voltage operation from 85...264V (wide range input) - High efficiency and power factor through switching mode technology - Powers from 150W to 1200W - Charging voltages: 12V, 24V, 36V, 48V - Programmable after customer's specifications
More specifications...
|
|
|
Chassis mount DC/DC converters, cooled by fan or air circulation, compact design, high power:
- 25W to 350W - Input voltages from 9,2V to 144V - Output voltages 5V, 12V, 24V, 48V
More specifications...
|
|
|
High performance Power supply 1.5kW - 12kW, 18V - 300V
A wide range of power supplies for nearly every requirement.
- Powers from 80W to 12kW - Currents from 0,4A to 300A - Voltages from 18V to 300V (or even higher, by request) - 19" and desktop models with 2/3/6/9HE - Custom designs possible - Programmable via analogue interface, USB, IEEE, RS232 or CAN - Exchangable interface cards with LabView support - Special version ZH with active load (2400W peak pulse power) and high voltage dynamics, as well as [...]
More specifications...
|
|
|
Laboratory DC power supply 80W - 640W, 16V - 150V
Compact and powerful laboratory power supplies for applications in R&D, schools, workshops and test environments. With analogue interface, current/voltage seperately adjustable from 0...max.
- Voltages from 16V to 150V - Currents from 2,5A to 40A - Powers from 80W to 640W - Analogue interface - Illuminated LCD or LED displays - Additional outputs - Parallel or series connection - High stability - Linear and switched mode versions (with wide [...]
More specifications...
|
|
|
DIN rail power supplies with high performance and compact dimensions, in linear or switching technology. For instance, the 240W/24V/10A model come with PFC, 3-phase wide range input and are only 125 x 125 x 125mm.
- DC output: 12V or 24V fixed, 12...14V, 24...27V, 48...56V adjustable - AC input: 230V or 90..264 (wide range) - Powers from 6W to 960W - Linear and switching mode types - PFC - 3-phase variants - Remote sense - Power fail output
More specifications...
|
|
|
Powerful and compact inverters for the use in cars, camping, boating and everywhere, where no 230V mains is available.
- Powers from 80VA to 2000VA - Peak power up to 2500VA - Input voltages: 12V, 24V, 48V - Output 230V AC voltage (some models with pure sine) - E-Mark approval for the use in cars - various safety features for overload, undervoltage etc.
More specifications...
|
|
|
Battery-buffered uninterruptable power supply (UPS)
A wide range of AC UPS series, from small power for home users to highest performance for industrial applications are available.
- Line Interactive principle with Boost & Buck or Online principle with double conversion - 1ph/1ph, 3ph/1ph or 3ph/3ph - AC input : 230V or wide range - AC output: 220/230V @ 50/60Hz (also as frequency converter) - Powers from 500VA to 300kVA - External, configurable battery cabinets - RS232 with supervision software - [...]
More specifications...
|
|
|
The new, electronic loads of the series EL3000A and EL9000A offer, amongst the standard features of electronic loads, some new and interesting functions. Three voltage classes and multiple power classes are rounding the selection up. The model BFC 2000 even offers a mains backfeed.
- DC input voltage: 0...80V, 0...160V, 0...400V - Powers: 400W, 2400W, 4800W, 7200W - Currents up to 600A - Fan-cooled - 2U/4U/6U, 19" rack housing for the 2400/4800/7200W [...]
More specifications...
|
|
|
Universal power supply
Ideal for home use, schools, laboratories or R & D facilities. Robust design, digital LED volt- and amperemeters, extra outputs and closed housing for improved safety.
- AC and DC outputs, continuously adjustable - Outputs: 0..32V DC/AC and 0...300V DC/AC - Extra outputs: 3/12/18/24V AC - Currents: 0...2A or 0...5A - Galvanically isolated - Filtering switchable
More specifications...
|
Industrial categories of this manufacturer: | DC / DC converter | Power supply | DIN rail power supply | DC / AC inverter | Electronic DC load |
Copyright © DirectIndustry
|