The new software EA Power Control can be used to remotely control various  device series. It is available for free and compatible to following device series (including soon to be published ones):

 

  • EL 3000 B
  • EL 9000 B / EL 9000 B HP / EL 9000 B 2Q
  • EL 9000 DT
  • EL 9000 T
  • ELR 5000
  • ELR 9000
  • PS 3000 C
  • PS 5000
  • PS 9000 1U / 2U / 3U
  • PS 9000 T
  • PSB 9000
  • PSE 9000
  • PSI 5000
  • PSI 9000 DT
  • PSI 9000 T
  • PSI 9000 2U - 24U

 

The software offers these features:

  • Seperate remote control of up to  10 devices at once, even of different type
  • Manage the most important device settings
  • Display of all actual values (U, I, P, R)
  • Input of set values (U, I, P, R) and alarm thresholds (OVP, OCP, OPP)
  • Setting remote control on/off, setting DC input/output on/off
  • Status (regulation mode, alarms, DC input/output condition)
  • Control all features of the device remotely with commands (SCPI or ModBus)
  • Sequencing & Logging (semi-automatic table control and data acquisition)
  • Master-slave support for series with digital master-slave bus (config, init, master shows system ranges)
  • Multi Control (purchasable extra feature, see below for details)
  • Complete remote control of the function generator or sequence generator of ELR 5000 (purchasable extra feature)
  • Visualisation of actual and set values on a graphical plot area, with data save features as picture or CSV (purchasable extra feature)
  • Installer for .NET framework and USB driver
  • Demo mode (open all windows without an actual device connected)
  • 14-day test period (upon requesting a trial licence)

 

With the add-on Multi Control you can:

  • Control and monitor up to 20 devices of any model from the supported series in one window
  • Build groups of any number of devices of the max. 20 units in order to assign different values to the groups
  • Apply semi-automatic remote control (Sequencing) on any number of the max. 20 units
  • Configure and use the function generator for any number of the max. 20 units (the units must feature a built-in function generator)
  • Open and show the Graph for any number of the max. 20 units, to visually compare recorded data
  • Record data (Logging) from any number of the max. 20 units
  • Automatically unlock the "Function Generator" app and the "Graph"

 

View EA Power Control history

 

Minimum requirements:

  • Windows 7 or newer
  • CPU 2GHz or better, 1GB RAM
  • Microsoft .NET Framework Version 4.5 or newer
  • Compatible device with USB or Ethernet port

 

 

 EA Power Control 2.11

 

 EA Power Control manual (PDF, en, de, ru, cn)

 Firmwares

 

Screenshots: