Conventional Electronic Loads - EL 3000 B


 

 

Technical specifications

Input power rating 

400W

 

Input voltages  

80V, 200V, 500V

 

Currents  

up to 0-60A

Main-Features

Function generator
Portable with tilt stand
Optional interface: USB, Ethernet or Analog

Description

  • Microprocessor (FPGA) controlled
  • Multilingual colour TFT panel
  • LabView VIs and remote control software (Windows)


All products and technical details in our product catalog



Electronic Load with energy recovery - ELR 9000 HP 3U


 

 

Technical specifications

Input power ratings  

5000W bis 15000W

 

Input voltages  

80V, 200V, 360V, 500V, 750V, 1000V, 1500V

 

Currents  

up to 0-510A

Main-Features

ƒƒMaster-slave bus for parallel connection


19" full sized module, 3 unit height

Analogue- and USB-interface, further options available

Description

  • Microprocessor (FPGA) controlled
  • Multilingual colour touch panel
  • Analogue and digitale interfaces
  • Integrated function generatorƒƒ with predefined wave forms, such as sinus, triangle, rectangle, trapezoid, ramp, arbitrary
  • Highly isolated built-up


All products and technical details in our product catalog



Bi-directional laboratory power supply with energy recovery - PSB 9000 3U


 

 

Technical specifications

Power ratings  

5000W bis 15000W

 

Voltages 

60V, 80V, 200V, 360V, 500V, 750V, 1000V, 1500V

 

Currents  

up to 0-360A

Main-Features

ƒƒMaster-slave bus for parallel connection


19" full sized module, 3 unit height

Analogue- and USB-interface, further options available

Description

  • Microprocessor (FPGA) controlled
  • Multilingual colour touch panel
  • Internal resistance regulation
  • Battery test mode
  • Arbitrary-Generator & car-starting curve
  • Optional: ƒƒDigital plug & play interfaces
  • SCPI & ModBus supported
  • LabView VIs and remote control software (Windows)


All products and technical details in our product catalog



Conventional Electronic Loads - EL 9000 B HP 2U


 

 

Technical specifications

Input power ratings 

600W up to 2400W

 

Input voltages 

80V, 200V, 360V, 500V, 750V

 

Currents 

up to 0-170A

Main-Features

ƒƒMaster-slave bus for parallel connection

19" full sized module, 2 unit height

ƒƒGalvanically isolated interfaces (analog and USB)

Description

  • Microprocessor (FPGA) controlled
  • Multilingual colour touch panel
  • ƒMaster-slave bus for parallel connection
  • Optional: ƒƒDigital plug & play interfaces
  • SCPI & ModBus supported
  • LabView VIs and remote control software (Windows)


All products and technical details in our product catalog



DC laboratory power supplies - PS 9000 T 320W-1500W


 

 

Technical specifications

Output power ratings 

320W, 640W, 1000W, 1500W

 

Output voltages 

40V, 80V, 200V, 500V

 

Currents 

up to 0-60A

 

 

 

Main-Features

Auto-ranging

Space saving tower style-housing

Colour touch panel

Description

  • ƒƒWide input voltage range 90...264 V with active PFC
  • High efficiency up to 92%
  • USB port as standard, Ethernet & analog optional
  • LabVIew-VIs
  • ƒ40 V models compliant to SELV (EN 60950)


All products and technical details in our product catalog



DC laboratory power supplies - PSI 9000 T 320W-1500W


 

 

Technical specifications

Output power ratings 

320W, 640W, 1000W, 1500W

 

Output voltages 

40V, 80V, 200V, 500V

 

Currents 

up to 0-60A

 

 

 

 

Main-Features

Auto-ranging

Space saving tower style-housing

Colour touch panel

Description

  • Wide input voltage range 90...264 V with active PFC
  • ƒƒHigh efficiency up to 92%ƒƒ
  • Integrated function generatorƒƒ
  • Internal resistance simulation and regulation
  • LabVIew-VIsƒƒ
  • 40 V models compliant to SELV (EN 60950)


All products and technical details in our product catalog



Conventional Electronic Loads - EL 9000 T


 

 

Technical specifications

Input power ratings 

400W up to 600W

 

Input voltages 

80V, 200V, 500V

 

Currents 

up to 0-45A

 

 

 

Main-Features

ƒƒTrue function generator

Space saving tower-style housing

USB-interface

Description

  • Microprocessor (FPGA) controlled
  • Multilingual colour touch panel
  • Adjustable protections: OVP, OCP, OPP
  • Ethernet & analog interface optional
  • SCPI & ModBus supported
  • LabView VIs and Control software (Windows)


All products and technical details in our product catalog



Conventional Electronic Loads - EL 9000 B 2Q


 

 

Technical specifications

Input power ratings 

600W up to 2400W

 

Input voltages 

80V, 200V, 360V, 500V, 750V

 

Currents 

up to 0-170A

Main-Features

Two-quadrants module

19" full-sized module
2 units height

Analog and USB interface

Description

  • Micro-processor (FPGA) controlled
  • Control panel with status LEDs
  • Master-slave bus for parallel connection
  • Optional: Digital plug & play interfaces
  • SCPI & ModBus supported
  • LabView VIs and remote control software (Windows)
     


All products and technical details in our product catalog



Conventional Electronic Loads - EL 9000 DT


 

 

Technical specifications

Input power ratings 

400W up to1200W

 

Input voltages 

80V, 200V, 360V, 500V, 750V

 

Currents 

up to 0-60A

Main-Features

For laboratories, schools or workshops

Desk top housing with carrying handle and tilt stand

Colour TFT touch panel

Description

  • Micro-processor (FPGA) controlled
  • High accuracy and resolution
  • Including function generator
  • Ethernet, USB and analogue interface built-in
  • Software EA Power-Control included
     


All products and technical details in our product catalog



Low noise DC laboratory power supplies - PSI 9000 DT 320W-1500W


 

 

Technical specifications

Output power ratings 

320W, 640W, 1000W, 1500W

 

Output voltages 

40V, 80V, 200V, 360V, 500V, 750V

 

Currents 

up to 0-60A

Main-Features

Autoranging

Desktop housing with carrying handle and tilt stand

Colour TFT touch panel

Description

  • Wide input voltage range 90...264 V with active PFC
  • Low noise
  • Integrated function generator
  • Battery internal resistance simulation
  • 40V models compliant to SELV (EN 60950)

 



All products and technical details in our product catalog



Power-Systems - PSI 9000 15U-24U 30-90 kW


 

Technical specifications

Output power ratings 

30 kW, 45 kW, 60 kW, 75 kW, 90 kW

 

Output voltages

80 V, 200 V, 360 V, 500 V, 750 V, 1500 V

 

Currents 

up to 0-3060 A

Main-Features

Autoranging

Turnkey-ready

Colored Touchscreen

Description

  • For three-phase mains supply 400 V and 50/60 Hz
  • Pre-configured, pre-wired, turn-key ready compliant to EN60950

Basing upon power supply of series PSI 9000 3U, featuring

 

  • Versatile function generator with ample simulations (PV, -fuel cell, -battery)
  • Built-in USB and analog interface
  • Plug'N'Play slot for optional interface retrofitting: e.g. Ethernet, CAN, CanOpen, Profibus, Profinet, RS232 and more
  • Intuitivly operational HMI with coloured TFT-touch panel.

Click here to see our system advantages to ease your decision.



All products and technical details in our product catalog



Innovative Conventional Electronic Loads - EL 9000B 3U


 

Technical specifications

Input power ratings 

up to 7200 W

 

Input voltages 

80 V up to 750 V

 

Currents 

- - -

Main-Features

Autoranging

High dynamic

Colored Touchscreen

Description

  • micro-processor (FPGA) controlled
  • high accuracy and resolution (16Bit)
  • active input oscillation suppression and protective input filter
  • true master- slave parallel operation
  • TFT Touch Display
  • plug’n play interface slot


All products and technical details in our product catalog



Modular Electronic Load with Energy Recovery - ELR 5000M 6U


 

Technical specifications

Input power ratings 

up to 0-320W per module 

 

Input voltages 

0-80V or 0-200V

 

Currents 

0-12A or 0-25A

Main-Features

Autoranging

Energy-Recovery

Colored Touchscreen

Description

  • Modular energy-recovery electronic loads, 80V and 200V 
  • up to 10 channels each 320W
  • micro-processor controlled
  • Ethernet Interface
  • TFT Touch Display
  • total load power 3200W
  • energy recovery up to 3000W


All products and technical details in our product catalog



EA Power Control - Remote control software for current device series


 

Recent Software

The free base version of the remote control software EA Power Control is now available as download. 



Download

 EA Power Control


New DC Laboratory Power Supply - PS 9000 1U


 

Technical specifications

Output power ratings 

1.5 kW or 3 kW

 

Output voltages 

up to 750 V DC

 

Currents 

up to 100 A

Main-Features

Autoranging

Ultra compact

Colored Touchscreen

Description

  • Adjustable, programmable
  • ultra-compact 1U 19"-rack format
  • “Auto-ranging” output
  • 3-way interface (Analogue/USB/Ethernet)
  • highly isolated built-up
  • fast µ-processor controller, up to 16 bit resolution


All products and technical details in our product catalog



Electronic loads with energy recovery function - ELR 9000 3U


 

Technical specifications

Input power ratings 

3,5 kW up to 210 kW

 

Input voltages 

up to 1500 V

 

Currents  

5100 A

Main-Features

Autoranging

Energy-Recovery

Colored Touchscreen

Description

The electronic load series EL 9000 has been complemented by a new series of e-loads with recovery function (feedback into the grid)

The new ELR 9000 3U series comprises 14 models with load powers up 10.5kW DC input voltages up to 1500V and DC input currents of up to 510A

On-board standard fittings include USB interface, function generator and a slot to retrofit digital interfaces in modular style.

  • 19” 3U housing or 19” 42U system rack
  • Graphical display with touch function
  • On-board analogue and USB interface
  • Optional digital interface cards for retrofitting: CAN/CANopen/RS232/USB/Ethernet/Profibs/Modbus


All products and technical details in our product catalog


Tech Special

AUTORANGING

* Flexible Output Power Stage

* Always max. power availability

* Serves a larger number of EUTs

* Up to 3 times higher power

More information



Tech Special

ENERGY RECOVERY



* Substantially cost saving
* Efficiency up to 95%
* Fast amortisation

* Ecologically friendly